请使用支持JavaScript的浏览器!
主营:分子类,蛋白类,抗体类,生化类试剂
℡ 4000-520-616
℡ 4000-520-616
indoor biotechnologies/Ara h 3 ELISA 2.0 kit - Single plate (EPC-AH3-1)/1/EPC-AH3-1
产品编号:EPC-AH3-1
市  场 价:¥9900.00
场      地:美国(厂家直采)
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:$495.00
品      牌: indoor biotechnologies
公      司:indoorbiotechnologies
公司分类:
indoor biotechnologies/Ara h 3 ELISA 2.0 kit - Single plate (EPC-AH3-1)/1/EPC-AH3-1
商品介绍

ELISA 2.0 kit for measuring Arachis hypogaea allergen, Ara h 3.

Antibodies:1E8/4G9
Standard Range:125-0.49 ng/mL
Limit of Detection:1.9ng/mL
Background:OD<0.08 at 450nm
Coefficient of Determination:R-squared>0.98
Contents:

Plate: Pre-coated with anti-Ara h 3monoclonal antibody 1E8Vial 1: (white top) Ara h 3 allergen standardConcentration: 1250 ng/mlVial 2: (brown) anti-Ara h 3 antibody 4G9Vial 3: (blue top) Streptavidin-PeroxidaseBottle 1: Wash buffer, (10x concentrate)Bottle 2: Assay buffer, (10x concentrate)Bottle 3: TMB developing substrateBottle 4: Stop solution (0.5N sulfuric acid)

Storage:The ELISA 2.0 kit should be stored at 2-8°C.
Expiry:6 months from date of receipt
Not Provided:

Type I ultrapure water or 18.2MΩ de-ionized waterVolumetric measuring equipment (e.g. serological pipette, graduated cylinder)Clean containers for buffer and reagent preparationCalibrated single and multi-channel micropipettes and tipsVortex mixerPlate reader capable of reading absorbance at 450nmAnalysis software (recommended, but not required)

Notes:The allergen standard is recommended for immunoassay calibrationpurposes only.A list of frequently asked questions and troubleshooting guide can be found under the ‘Support’ tab on our website.
Product Resources:

EPC-AH3-1 Certificate of Analysis

Validation Performance Data

For research and commercial use in vitro:not for human in vivo or therapeutic use.

Certificate of Analysis
Pre-coated Plate:96-well polystyrene microtiter plate coated withmonoclonal antibody 1E8 and treated with stabilizingagent. Sealed in foil pouch with desiccant.
Monoclonal Antibody:1E8
Immunogen:Ara h 3
Isotype:Mouse IgG1
Specificity:Binds to an epitope on peanut allergen, Arachis hypogaea, Ara h 3.
Purification:Produced in tissue culture and purified by affinity chromatography using Protein A. Single heavy and light chain bands on SDS-PAGE.

Certificate of Analysis
Detection Antibody:4G9
Immunogen:Ara h 3
IsotypeMouse IgG1
Specificity:Binds to an epitope on peanut allergen, Arachis hypogaea, Ara h 3.
Activity:Biotinylated and titrated for use in ELISA at 1/1000 dilution. Prepared in 1% BSA/50% glycerol/PBS, pH 7.4, 0.22 μm filtered, preservative free.

Certificate of Analysis
Allergen Standard:Purified natural Ara h 3 prepared in 1% BSA/50%glycerol/PBS, pH 7.4.
Concentration/Calibration:1,250 ng/mL (based on amino acid analysis)
References:
1. Perry TT, Conover-Walker MK, Pomés A, Chapman MD, Wood RA. Distribution of peanut allergen in the environment. J Allergy Clin Immunol. 2004 May;113(5):973-6.
2. Maloney JM, Chapman MD, Sicherer SH. Peanut allergen exposure through saliva: assessment and interventions to reduce exposure. J Allergy Clin Immunol. 2006 Sep;118(3):719-24.

品牌介绍

Indoor Biotechnologies 由三家附属公司组成,INDOOR Biotechnologies Inc.(IBI),位于美国弗吉尼亚州夏洛茨维尔,INDOOR Biotechnologies Limited(IBL)位于英国卡迪夫,INDOOR Biotechnologies India(IBIndia),新设立于班加罗尔。Indoor Biotechnologies 遍布全球,在日本,中国和韩国拥有授权分销商,在全球约50个国家/地区销售。 Indoor Biotechnologies 生产纯化的天然和重组过敏原,用于研究和开发过敏诊断和疫苗。该产品系列目前包括 50 种纯化的过敏原,其制造具有高纯度和生物活性。这包括具有低内毒素含量的 LoTox™ 过敏原,专为过敏和哮喘的免疫学研究而设计。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔